What is a quality inspection report?
It is a qualified product quality inspection report issued by a state-certified testing agency after testing the quality of the product according to the corresponding quality standards and using the testing methods specified by the state. The quality inspection report can be provided to the agent or provided to the network mall, which can not only enhance the competitiveness of the product, but also allow consumers to rest assured that the product, so many customers will choose to do the relevant test report. Lighting products need to be sold on the e-commerce platform is also required to handle the quality inspection report.
Lighting quality inspection report standards:
Lighting quality inspection report, generally with reference to the GB7000 standard, or testing EMC electromagnetic compatibility, IP rating, luminous flux and other performance.
Lighting quality inspection report uses:
1. luminaire quality inspection report can be used to station in Jingdong, Taobao, Tmall, Ali, Amazon, ebay, Walmart, Xiaomi Mall, Jindo and other e-commerce platforms.
2. Bidding: Lighting quality inspection report can be used for bidding projects of government departments, institutions and public units
3. Enter large supermarkets or stores
4. audit certificate, apply for government subsidies
5. Lighting quality inspection report for industrial and commercial quality inspection and market supervision
6. Domestic market sales, qualification, etc.
Lighting quality inspection report for products:
Lighting products that require quality inspection reports for lamps and lanterns:
1. Fixed lamps and lanterns (chandeliers, ceiling lights, ceiling lights, wall lights, rail lights, emergency lighting, etc.)
2. Embedded lamps and lanterns (grille lamps, downlights, corner lamps and lanterns, wall cabinets, etc.)
3. Mobile lamps and lanterns (table lamps, LED table lamps, floor lamps, clip lamps, etc.)
4. street lights or street lighting, floodlights, spotlights, landscape lights, garden lights, string lights and other lamps, energy-saving lamps, LED power supply, self-ballasted or non-self-ballasted LED lamps, LED modules, etc. ... (Outdoor lighting quality inspection report in addition to testing the safety aspects, but also need to assess the dust and water resistance, environmental reliability, anti-aging and other performance.)
Luminaire quality inspection report testing items:
1, lighting safety test items:
Impact test, moisture test, insulation resistance test, electrical strength test, ball pressure test, normal temperature rise test, abnormal temperature rise test, waterproof and dustproof test, combustion resistance test, mechanical test, component failure test, etc.
2、Lamp EMC test items
Insertion loss, nuisance voltage, 9KHz-30MHz radiation electromagnetic disturbance, 30MHz-300MHz radiation electromagnetic disturbance, harmonic current, voltage fluctuation and flicker, electrostatic discharge, radio frequency electromagnetic field, electric fast transient pulse group, surge, injection current, industrial frequency magnetic field, voltage transient and short interruption.
Lamp County Quality Assurance Report Related Standards
IEC/EN62471 is intended to assess the light radiation hazards associated with different lamps and lamp systems, and fully replace the IEC/EN60825 standard on the energy level of LED products, adding photobiological aspects of the requirements, including radiation intensity, radiation brightness, etc., and according to test data on the product hazard classification, including exemption level, low hazard, medium hazard, high hazard level.
The EU part of the standard EN62471: 2008 has been implemented in 2009.09.01, EN60825 on LED part has been completely invalidated in 2010.09.01.
IEC/EN60825 is mainly for single wavelength of light for energy test calculation.
IEC/EN62471 is mainly on the broad band of light measurement, and integrated human eye and skin response to light time, angle, sensitivity and other aspects of the calculation of the light County class into the renewal of Taobao Tmall quality inspection report need to test the project are: logo, structure, grounding, protection against electric shock, insulation resistance and electrical strength, leakage current, creepage distance and electrical gap, impact test, durability test, the Ball pressure test, needle flame test, component temperature test, wiring method installation method and other safety tests.
The luminaire should comply with one of the standards in GB 7000 part 2. If the GB 7000 Part 2 does not correspond to a particular luminaire or a group of luminaire standards, the GB 7000 Part 2 of the most similar suitable standards can be used as a guide to the requirements of the luminaire and the test.
If there are two or more standards in GB 7000 part 2 applicable to the designed luminaire, the luminaire should meet two or all applicable standards.
Based on the test purpose, half of the luminaire should be treated as a luminaire.
Different luminaires correspond to different testing standards, the following is a brief list of some luminaire testing standard numbers.
GB7000.1-2015, that is, the luminaire Part 1: General requirements and test, specifies the general requirements for the use of electric light sources, power supply voltage does not exceed 1000V lamps and lanterns. The requirements and related tests proposed in this part include:Classification, marking, mechanical structure, electrical structure and photobiological safety.
GB7000 Part 2 of each standard details the specific requirements for a particular type of luminaire or group of luminaires with a supply voltage of not more than 1000V. For the purpose of revision, these parts are published separately, and additional parts are added when required.
IEC 60598 Part 2 (GB7000 Standard Special Requirements Section) Table of Contents
Part 2-1: Fixed general purpose luminaires (GB 7000.201)
Part 2-2:Recessed luminaires (GB 7000.202)
Part 2-3: Road and street lighting fixtures (GB 7000.203)
Part 2-4: Removable general-purpose lamps and lanterns (GB 7000.204)
Part 2-5: Flood light fixtures (GB 7000.7)
Part 2-6: With built-in tungsten transformer or converter lamps and lanterns (GB 7000.6) (see note)
Part 2-7: Garden with removable lamps and lanterns (GB 7000.207)
Part 2-8: Handheld lamps (GB 7000.208)
Part 2-9:Photographic and film lamps and lanterns (non-professional use)(GB 7000.19)
Part 2-10: Children's removable lamps and lanterns (GB 7000.4)
Part 2-11: Aquarium lamps and lanterns (GB 7000.211)
Part 2-12: Electrical socket mounted night lights (GB 7000.212)
Part 2-13: Ground recessed lighting (GB 7000.213)
Part 2-14: The use of cold cathode tubular discharge lamps (gram rainbow lamps) and similar devices for lamps and lanterns (GB 7000.214)
Part 2-15:Not currently in use
Part 2-16:Not currently in use
Part 2-17:Stage lighting, television and film and photography places (indoor and outdoor) with lamps and lanterns (GB 7000.217)
Part 2-18: Swimming pools and similar places with lamps and lanterns (GB 7000.218)
Part 2-19: Ventilated lamps and lanterns (GB 7000.219)
Part 2-20: String lights (GB 7000.9)
Part 2-21:Sealed light strings 1)
Part 2-22:Emergency lighting lamps and lanterns (GB 7000.2)
Part 2-23:Tungsten filament lamp special low-voltage lighting system (GB 7000.18)
Part 2-24: Limit the surface temperature of the lamps and lanterns (GB 7000.17)
Part 2-25: Hospitals and rehabilitation building clinics with lamps and lanterns (GB 7000.225)